- “SET TEMP” shows the target temperature.
NOTE: If you are not using the TCS-1000 inside of a plastic tub as a temperature controlled water bath you will need to increase the target temperature +1°F/.5°C for every 3min. of development and pre-soak film in the tank with heated rinse water while the developer is being heated.
- Tap the power button. You will hear a beep sound and the current temperature will stop blinking. The TCS-1000 is now mixing and heating. The alarm will beep when the liquid temperature reaches the same as target temperature.
- Tap the power button when finished, the current temperature will flash and the TCS 1000 will stop circulating.